Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.558
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38564965

RESUMO

In the present work, a new microextraction procedure combined with gas chromatography-mass spectrometry has been developed for the analysis of several aliphatic amines from urine sample. The sample preparation method was a continuous homogenous liquid phase microextraction that was based on in-situ preparation of 4-chlorophenol: choline chloride deep eutectic solvent. The deep eutectic solvent was prepared by passing the mixture of related compounds through a syringe barrel filled with exothermic salts (calcium chloride and potassium bromide). The released heat by dissolving the salts and increasing the solution ionic strength assists the formation of the deep eutectic solvent. The influence of various factors on the efficiency of the proposed procedure including salts amount, flow rate, pH, salting-out effect, and extraction solvent volume was studied. The calibration curves were linear broadly over the concentration range of 1.2-250 ng mL-1 with coefficient of determinations ≥0.996. The enrichment factors were in the range of 188-246 and the limits of detection and quantification were 0.16-0.37 and 0.56-1.2 ng mL-1, respectively. Based on the results, the offered method was sensitive, rapid, eco-friendly, and efficient for extracting and determining aliphatic amines in urine samples.


Assuntos
Microextração em Fase Líquida , Solventes/química , Microextração em Fase Líquida/métodos , Cromatografia Gasosa-Espectrometria de Massas/métodos , Solventes Eutéticos Profundos , Sais , Colina , Limite de Detecção
2.
Environ Monit Assess ; 196(5): 454, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622372

RESUMO

This work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 µg kg-1, 150.6 µg kg-1, 45.2 µg kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.


Assuntos
Microextração em Fase Líquida , Poluentes Químicos da Água , Cromatografia Gasosa-Espectrometria de Massas/métodos , Águas Residuárias , Fenitoína/análise , Poluentes Químicos da Água/análise , Monitoramento Ambiental/métodos , Solventes/química , Água/análise , Microextração em Fase Líquida/métodos , Limite de Detecção
3.
Food Chem ; 447: 139024, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38493687

RESUMO

This manuscript describes the development of a novel liquid phase microextraction (LPME) method for the extraction and determination of Zn (II), Fe (II), Pb (II), and Cd (II) in various infant/baby food and supplements products. The method is based on vortex-assisted extraction combined with a switchable-hydrophilicity solvent (SHS) sample preparation. The SHS, which undergoes reversible phase changes triggered by pH change, enables selective extraction and easy phase separation. A flame atomic absorption spectroscopy was used in the final determination step. Optimization studies revealed, that the optimal pH of the sample solution (after digestion) during analytes extraction is 5.5. A l-proline is added to the sample (375 mM) to ensure the complexation of the target metal cations. After the complexation step, 750 µL of SHS - a N, N-Dimethylcyclohexylamine along with 0.9 mL of 2 M of acetic acid solution is added (hydrophilicity switch-on stage) and mixed manually to obtain a homogeneous solution. In the last stage, 0.45 mL of 10 M NaOH solution (hydrophilicity switch-off stage) is added to the sample solution and a vortex for 100 s is applied to ensure the effective extraction and separation of the complex containing the analytes. At this stage, a cloudy solution is immediately obtained. Finally, the effective phase separation is obtained at the centrifugation step (4000 rpm for 2 mins). The method limit of detection was as 0.03, 0.009, 0.6, and 0.2 ng/L for Zn (II), Fe (II), Cd (II), and Pb (II) respectively with RSD% below 2.0 %. The analysis of certified reference materials and real samples proved the full applicability of the method for routine analysis, contributing to the field of heavy metal analysis and ensuring the safety of baby products. According to the AGREE methodology, this method can be named as green analytical chemistry method with a score of 0.77.


Assuntos
Cádmio , Microextração em Fase Líquida , Humanos , Solventes/química , Chumbo , Microextração em Fase Líquida/métodos , Alimentos Infantis , Interações Hidrofóbicas e Hidrofílicas , Zinco , Limite de Detecção
4.
Food Chem ; 447: 139036, 2024 Jul 30.
Artigo em Inglês | MEDLINE | ID: mdl-38518615

RESUMO

In this study, a UV-Vis Spectroscopy-based method was developed for the determination of tin(IV) in epilobium parviflorum tea samples after preconcentration. The preconcentration process was carried out using the liquid-liquid microextraction technique. Before starting the analysis, optimization studies were carried out for the variables likely to affect the experimental results. As a result of the analyzes performed under optimum conditions, the detection limit of our method was calculated as 16.83 µg/L. The percent relative standard deviation value was calculated as 1.25% (n = 8) and linearity was found in the range of 10-1000 µg/L. Recovery experiments were performed on epilobium parviflorum tea samples using the matrix matching method. As a result of the analyzes made on teas belonging to three different brands, recovery results ranging from 92 to 117% were obtained.


Assuntos
Epilobium , Microextração em Fase Líquida , Solventes , Solventes Eutéticos Profundos , Estanho , Microextração em Fase Líquida/métodos , Análise Espectral , Chá , Limite de Detecção
5.
Artigo em Inglês | MEDLINE | ID: mdl-38547699

RESUMO

In this research, a method known as a hollow fiber-liquid-phase microextraction was employed to extract and concentrate free metoprolol from plasma samples. The extracted analyte was subsequently determined using high-performance liquid chromatography coupled with a diode-array detector. Several parameters, including hollow fiber length, sonication time, extraction temperature, and salt addition, were investigated and optimized to enhance extraction efficiency. After extracting the analyte under optimum conditions from plasma samples, the enrichment factor and extraction recovery were 50 and 86 %, respectively. Moreover, the method exhibited detection and quantification limits of 0.41 and 1.30 ng mL-1, respectively. The analysis of real samples demonstrated satisfactory relative recoveries in the range of 91-99 %.


Assuntos
Microextração em Fase Líquida , Metoprolol , Microextração em Fase Líquida/métodos , Cromatografia Líquida de Alta Pressão/métodos , Cloreto de Sódio , Sonicação
6.
Chemosphere ; 354: 141706, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38484993

RESUMO

Aliphatic aldehydes are a class of organic compounds containing aldehyde groups, which are widespread, and closely related to people's daily life and health. In this work, a series of terpenes based hydrophobic deep eutectic solvents were designed and synthesized using hexafluoroisopropanol as hydrogen bond donor and menthol/thymol as hydrogen bond acceptor. Then they are used as extraction solvent in dispersive liquid-liquid microextraction for extracting and determining seven aliphatic aldehydes from drinking water and alcoholic beverage combined with high performance liquid chromatography-ultraviolet. Due to the fact that these hydrophobic deep eutectic solvents are liquid at the room temperature, a density greater than that of water, a lower viscosity (≤26.10 mPa s, 25 °C), after extraction and centrifugation, the microvolume DES-rich phase in the bottom is convenient for collection and direct analysis without further dissolution or dilution with organic solvents. Some factors affecting the extraction recovery were optimized by one-variable-at-a-time and response surface methodology. Under the optimal conditions, the enrichment factors for the seven aliphatic aldehydes were 48-56. The method had good performance: linear ranges of 1.0-200, 0.5-200, 0.2-200, 0.4-400, 1.0-400, 0.4-400 and 0.4-400 µg L-1 for seven aliphatic aldehydes (r2 ≥ 0.9949), limits of detection of 0.1-0.5 µg L-1, intra-day and inter-day precisions <4.9%. The recoveries of seven aliphatic aldehydes ranged from 76.0 to 119.0%. The proposed dispersive liquid-liquid microextraction method is simple, rapid, highly efficient, and green, which effectively reduces the amount of toxic chemical reagents used and their impact on the environment. Rapid and efficient detection of aliphatic aldehydes helps ensure a healthy diet and has great application prospects in food safety analysis.


Assuntos
Água Potável , Microextração em Fase Líquida , Humanos , Terpenos , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Aldeídos , Limite de Detecção , Solventes/química , Cromatografia Líquida de Alta Pressão/métodos , Bebidas Alcoólicas
7.
Talanta ; 273: 125847, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38452590

RESUMO

This study investigates the contamination of cow milk with aluminum (Al) and its potential health implications, particularly for children. Cow milk samples were collected from both nonexposed and exposed areas in Sindh, based on the source of livestock drinking water (fresh canals and groundwater). An environmental friendly deep eutectic solvent (DES) was used with ultrasonic-assisted dispersive liquid-liquid microextraction (UDLLµE) to enrich trace amounts of Al in whey milk and water samples. The enriched samples were then analyzed using inductively coupled plasma optical emission spectrometry. Certified reference materials were employed to validate the methodology, and the experimental results exhibited acceptable conformity. The DES-based dispersive liquid-liquid microextraction method was environmental friendly, devoid of acids and oxidizing agents, and used safe and inexpensive components for routine trace metal analysis in diverse samples. The resulting data revealed that Al in whey milk samples was observed in the range of 31-45 %, corresponding to (160-270) µg L-1 and (700-1035) µg L-1 in nonexposed and exposed whole cow milk samples, respectively. Additionally, it was observed that milk boiling in Al utensil for 10-20 min enhanced the Al levels from 3 to 8% of its total contents in milk samples.


Assuntos
Microextração em Fase Líquida , Leite , Criança , Bovinos , Animais , Humanos , Solventes/química , Leite/química , Soro do Leite , Alumínio/análise , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Limite de Detecção
8.
J Chromatogr A ; 1718: 464698, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38354504

RESUMO

Herein, we have developed a novel method of aqueous-sample dispersive liquid-liquid microextraction (AqS-DLLME) followed by sweeping micellar electrokinetic chromatography-tandem mass spectrometry (MEKC-MS/MS) for simultaneous determination of breast cancer drugs letrozole, anastrozole, palbociclib, ribociclib, abemaciclib, and fulvestrant in human plasma. Coupling of MEKC to MS was possible due to the use of ammonium perfluorooctanoate (APFO) as a volatile surfactant. The MEKC and MS conditions were optimized to achieve a fast, sensitive, selective, and green analysis enabling full separation of the analytes within 16 min. Electrophoretic buffer was 125 mM APFO at apparent pH 10.5 in 32 % MeOH, while sheath liquid was 70 % MeOH with 0.2 % formic acid, delivered at 10 µL/min. Excellent extraction recoveries from plasma ranging from 89.4 to 104.9 % were obtained with a combination of protein precipitation and DLLME. The developed method was validated according to the ICH guidelines. Remarkable selectivity, accuracy (bias < 6.7 %), precision (RSD < 15.8 %), and stability (bias < 10.4 %) with insignificant matrix effect (RSD < 14.0 %) and no carry-over were obtained over a wide range of concentrations. Linearity with inter-day slope RSD lower than 8.7 % was demonstrated. With this method, very low concentrations could be detected after the injection of only 68.7 nL of the sample. The method was applied to plasma samples from six women currently receiving breast cancer treatment. Determined concentrations of the drugs of interest agreed with concentrations found in clinical studies, thus proving the suitability of the developed method for therapeutic drug monitoring as a superior alternative to published LC-MS methods.


Assuntos
Neoplasias da Mama , Caprilatos , Cromatografia Capilar Eletrocinética Micelar , Fluorocarbonos , Microextração em Fase Líquida , Humanos , Feminino , Espectrometria de Massas em Tandem , Neoplasias da Mama/tratamento farmacológico , Cromatografia Capilar Eletrocinética Micelar/métodos , Microextração em Fase Líquida/métodos , Micelas
9.
Food Chem ; 445: 138694, 2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38364492

RESUMO

In this study, a novel ionic liquid (3-(3-chloro-2-hydroxypropyl)-1-butyl-1H-imidazol-3-ium hexafluorophosphate, (IL-2) was synthesized and characterized by FT-IR, NMR (1H,13C,31P) spectroscopy, and TGA. Two microextraction methods, ultrasonic assisted ionic liquid dispersive liquid liquid microextraction (USA-IL-DLLME) and ultrasonic assisted-temperature controlled ionic liquid DLLME, have been developed for preconcentration of Brilliant Blue FCF (E133) from some food products by the sythesized IL-2. For optimization of the both methods, several parameters such as volume of IL-2, pH, temperature, ultrasonication time, extraction time, centrifugation time, and salt effect were investigated. The obtained results for both methods under optimum conditions were compared. According to these results, the best limit of detection (4.55 µg L -1), enrichment factor (58), preconcentration factor (50), linear range (15-80 µg L -1), relative standard deviation % (1.15 %) were obtained by use of USA-TC-IL-DLLME method. Furthermore, the developed USA-TC-IL-DLLME method was succesfully applied to real samples for the preconcentration of Brilliant Blue FCF.


Assuntos
Benzenossulfonatos , Líquidos Iônicos , Microextração em Fase Líquida , Líquidos Iônicos/química , Microextração em Fase Líquida/métodos , Temperatura , Interleucina-2 , Espectroscopia de Infravermelho com Transformada de Fourier
10.
J Sep Sci ; 47(3): e2300745, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38356226

RESUMO

Understanding and comparing the applicability of electromembrane extraction (EME) and liquid-phase microextraction (LPME) is crucial for selecting an appropriate microextraction approach. In this work, EME and LPME based on supported liquid membranes were compared using biological samples, including whole blood, urine, saliva, and liver tissue. After optimization, efficient EME and LPME of clozapine from four biological samples were achieved. EME provided higher recovery and faster mass transfer for blood and liver tissue than LPME. These advantages were attributed to the electric field disrupting clozapine binding to interfering substances. For urine and saliva, EME demonstrated similar recoveries while achieving faster mass transfer rates. Finally, efficient EME and LPME were validated and evaluated combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The coefficient of determination of all methods was greater than 0.999, and all methods showed acceptable reproducibility (≤14%), accuracy (90%-110%), and matrix effect (85%-112%). For liver and blood with high viscosity and complex matrices, EME-LC-MS/MS provided better sensitivity than LPME-LC-MS/MS. The above results indicated that both EME and LPME could be used to isolate non-polar basic drugs from different biological samples, although EME demonstrated higher recovery rates for liver tissue and blood.


Assuntos
Clozapina , Microextração em Fase Líquida , Cromatografia Líquida , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Microextração em Fase Líquida/métodos , Membranas Artificiais
11.
J Chromatogr A ; 1717: 464686, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38310697

RESUMO

For the first time, benzophenone and related compounds were investigated in açaí-based food products. An extraction method based on the dilute-and-shoot approach, combined with the use of in-situ formed metal-containing ionic liquids (MCILs) followed by high-performance liquid chromatography, was developed and validated. A nickel and cobalt-based MCIL, in addition to the ratio of MCIL to lithium bis[(trifluoromethyl)sulfonyl]imide salt ([Li+][NTf2-]) for the ensuing metathesis reaction, were optimized. Parameters of the in-situ formed MCIL step, namely, the amount of MCIL, centrifugation time, and dilution step, were analyzed using a multivariate optimization approach, including central composite rotatable design and Derringer and Suich's tool. Optimum extraction performance was achieved using 50.98 mg of nickel-based MCIL and a MCIL to ([Li+][NTf2-]) ratio of 1:3 (m/m), a centrifuge time of 22 min, and 10.53 mL of water for the dilution step. This condition was used to perform analytical validation, which yielded satisfactory results with R2 ≥ 0.995, limits of detection (LOD) ranging from 0.0025 to 0.5 mg kg-1, and limits of quantification (LOQ) between 0.008 and 1.5 mg kg-1. The recovery rate ranged from 87 % to 107 % and precision values (as percent relative standard deviation) were equal or lower than 13 %. The validated method was applied to 25 samples of açaí-based food products purchased from Brazil and the United States. None of the samples showed analyte concentration levels above the LOD. The method's suitability was demonstrated for future monitoring of complex samples, such as foodstuffs.


Assuntos
Líquidos Iônicos , Microextração em Fase Líquida , Líquidos Iônicos/química , Níquel , Água/química , Metais , Cromatografia Líquida de Alta Pressão , Lítio , Íons , Benzofenonas , Microextração em Fase Líquida/métodos
12.
J Chromatogr A ; 1717: 464692, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38320432

RESUMO

A simple, fast, and efficient ultrasonic-assisted supramolecular solvent microextraction combined with high performance liquid chromatography method was developed for the determination of coumarins in Cortex fraxini, including esculin, esculetin and fraxetin. In this study, a novel supramolecular solvent was prepared with 1-octanol, tetrahydrofuran and water for the first time, and its composition, viscosity, density, structure, and micromorphology were characterized. The prepared supramolecular solvent exhibited vesicular structures and had the characteristics of low viscosity. Through single-factor experiments, response surface methodology and artificial neural network-genetic algorithm, the optimal extraction conditions were obtained as follows: NaCl concentration of 1 mol mL-1, pH value of 10, solid-liquid ratio of 10:1, vortex time of 30 s, ultrasonic power of 100 W, ultrasonic temperature of 60 °C, ultrasonic time of 15 min, centrifugation speed of 5000 rpm, and centrifugation time of 1 min. The results demonstrated that the artificial neural network model exhibited maximum R-values of 0.98703, 0.97440, 0.99836, and 0.95447 for training, testing, validation, and all dataset, respectively. The minimum mean square errors were 0.75, 10.15, 1.99, and 2.63, respectively. This indicated that the predicted values were almost consistent with the actual values. Under the optimal conditions, the total extraction yields of target analytes reached 2.80 %. The calibration curves for each analyte exhibited excellent linearity within the linear range (r > 0.9993). The limits of detection and quantification ranged from 4.87 to 6.55 ng mL-1 and 16.24 to 21.84 ng mL-1, respectively. The recoveries ranged from 98.71 % to 111.01 % with relative standard deviations of less than 3.6 %. The present method had the advantages of short extraction time (15 min) and less solvent consumption (0.5 mL). The prepared supramolecular solvent was proved to have great potential in extracting coumarins from medicinal plants.


Assuntos
Medicamentos de Ervas Chinesas , Microextração em Fase Líquida , Solventes/química , Ultrassom , Microextração em Fase Líquida/métodos , Cumarínicos , Medicamentos de Ervas Chinesas/química , Cromatografia Líquida de Alta Pressão/métodos , Algoritmos , Limite de Detecção
13.
Talanta ; 272: 125782, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38364568

RESUMO

The aim of the current study was to separate and determine arsenic in water and fish samples using a novel and green solidified floating organic drop microextraction (SFODME), which is based on switchable hydrophilicity solvent (SHS)-assisted procedure followed by hydride generation atomic absorption spectrometry (HG-AAS). The 4-((2-hydroxyquinoline-7-yl)diazenyl)-N-(4-methylisoxazol-3-yl)benzene sulfonamide (HDNMBA) and tertiary amine (4-(2-aminoethyl)-N,N-dimethylbenzylamine (AADMBA) were used as ligand and SHS, respectively. The use of SHS promotes quantitative extraction of arsenic complexes into an extraction solvent (1-undecanol). Some factors that impact extraction recovery were studied. Under optimal conditions, the limit of detection (LOD) and limit of quantification (LOQ) were 0.005 µg L-1 and 0.015 µg L-1, respectively. The calibration graph was linear up to 900.0 µg L-1 arsenic, with the enrichment factor is 267. The proposed SHS-SFODME methodology for arsenic quantification in water and fish samples was successfully implemented. The environmental friendliness and safety of proposed method were approved by the Analytical Greenness Calculator (AGREE) and the Blue Applicability Grade Index (BAGI) tools.


Assuntos
Arsênio , Microextração em Fase Líquida , Animais , Água/química , Solventes/química , Arsênio/análise , Espectrofotometria Atômica/métodos , Limite de Detecção , Peixes , Microextração em Fase Líquida/métodos
14.
J Chromatogr A ; 1719: 464753, 2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38394784

RESUMO

In this study, MIL-88(Fe) coordinated to carboxymethyl cellulose fibers was successfully synthesized, characterized, and utilized as a nanocomposite for the dispersive solid phase microextraction of butachlor and acetochlor. These analytes served as representative analytes for acetanilide herbicides (AHs) present in real samples. Effective parameters on the extraction efficiency were investigated to maximize the analytical performance of the developed method. Under optimized conditions, which encompassed sorbent amount of 12 mg, solution pH of 7.0, 4.0 min of the vortex time, 3.0 min of the extraction time, chloroform as desorption agent and no salt addition, the developed method exhibited remarkable figures of merit, such as high linearity (R2> 0.99), low limits of detection of 0.90 ng mL-1, substantial preconcentration factors (between 213 and 228), relative recoveries in the range of 90.8% to 109%, and good repeatability with relative standard deviations equal or below 7.2%. After validation, the developed method was applied to detect AHs in various cereal and agricultural soil samples.


Assuntos
Herbicidas , Microextração em Fase Líquida , Nanocompostos , Microextração em Fase Sólida/métodos , Herbicidas/análise , Carboximetilcelulose Sódica , Grão Comestível/química , Solo , Acetanilidas/química , Extração em Fase Sólida/métodos , Microextração em Fase Líquida/métodos
15.
Artigo em Inglês | MEDLINE | ID: mdl-38417274

RESUMO

Clomipramine (CLP) is a tricyclic antidepressant drug, and its determination in biological samples is of high importance in clinical and forensic evaluations to assure appropriate drug concentrations. In the present study, benzoic acid was employed as a pH-switchable hydrophilicity solvent (SHS) for the microextraction of CLP from authentic human urine samples prior to its determination by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The microextraction protocol was based on the phase transition of the SHS through pH alteration that resulted in its rapid dispersion and simultaneous phase separation. The obtained solid was collected in a syringe filter, dissolved in methanol, and analyzed. The main parameters that affected the efficiency of the microextraction procedure were studied and optimized to ensure high extraction efficiency for CLP and the analytical method was validated. Under optimum conditions, good linearity was observed between 0.05 and 5.0 µg mL-1. The limit of detection and limit of quantification were found to be 0.015 and 0.05 µg mL-1, respectively. The RSD values for intra-day repeatability and inter-day precision were 2.4-8.9 % and 1.7-9.1 %, respectively. The relative recovery values were within 90.0 and 110.0 % in all cases, demonstrating good method accuracy. The proposed SHS microextraction showed cost-efficiency, handling simplicity, and rapidity resulting in enhanced sample throughput. Moreover, the proposed method exhibited a green character and good applicability based on its evaluation by Green Analytical Procedure Index and Blue Applicability Grade Index.


Assuntos
Clomipramina , Microextração em Fase Líquida , Humanos , Clomipramina/urina , Solventes , Microextração em Fase Líquida/métodos , Interações Hidrofóbicas e Hidrofílicas , Cromatografia Líquida de Alta Pressão , Concentração de Íons de Hidrogênio , Limite de Detecção
16.
Anal Methods ; 16(11): 1593-1602, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38404220

RESUMO

In this study, a sample preparation procedure based on salt-induced homogeneous liquid-liquid extraction performed in a narrow-bore tube was used for the preconcentration and extraction of Zn(II), Cu(II), and Cd(II) ions from honey samples. To perform the procedure, a mixture of working solution containing sodium chloride, acetonitrile, and a synthesized deep eutectic solvent (as an extraction solvent) was transferred into a narrow tube filled with solid sodium chloride up to a specific level. As the solution flowed through the tube, tiny droplets of the extraction solvent were formed at the boundary between the solution and salt layer. The droplets moved upwards in the tube and eventually collected as a distinct layer on the top of the solution. The separated phase was removed and dispersed into ionized water. After centrifugation, tiny droplets of the extraction solvent containing the analytes were sedimented at the bottom of the tube. The concentrated analytes were measured using flame atomic absorption spectrophotometry. The linear ranges and extraction recoveries were obtained in the ranges of 1.5-100 µg kg-1 and 89.6-94.8%, respectively. The detection limits ranged from 0.35 to 0.48 µg kg-1. Low relative standard deviations (C = 10 µg L-1, n = 6) of 3.1, 2.8, and 3.4% for Zn(II), Cu(II), and Cd(II), respectively, were obtained. Finally, the optimized method was successfully used in determination of concentration of the selected heavy metal ions in various honey samples.


Assuntos
Mel , Microextração em Fase Líquida , Solventes , Cloreto de Sódio , Cádmio , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Extração Líquido-Líquido/métodos , Cloreto de Sódio na Dieta , Zinco
17.
Anal Methods ; 16(11): 1697-1707, 2024 Mar 14.
Artigo em Inglês | MEDLINE | ID: mdl-38421023

RESUMO

Performant sample preparation is mandatory in any leachable study to clean and preconcentrate analytes within the sample to offer the best possible extraction recovery as well the best precision for any given substance. The aim consists in developing a sample preparation method for hospital pharmacy-prepared drug products such as long-term storage prefilled syringes, vials and IV bags for the screening of leachable compounds. The Quality Control Laboratory of the Pharmacy of the Lausanne University Hospital (Switzerland) has developed a time- and cost-effective, highly sensitive, robust, and fast method using liquid chromatography coupled with high-resolution mass spectrometry (LC-HRMS) for the analysis of 205 plastic additives. An innovative setup, based on postcolumn infusion (PCI) using 2% ammonium hydroxide in methanol was used to boost the signal intensity of the analytes in MS detection. A database for extractable and leachable trace assessment (DELTA) was built to assist in the screening process of 205 plastic packaging-related compounds. The development of the sample preparation was based on 33 plastic additive candidates in different hospital pharmacy compounding solutions, and their extraction recovery rates as well as their relative standard deviation were taken into consideration. In conclusion, the developed DLLME was assigned with ultrasound assistance and triple extraction, which brought about extraction recovery rates between 67% and 92%, a good RSD <10%, and a preconcentration factor of 50×. Therefore, DLLME could be considered suitable for the semiquantitative screening of leachable additives in simple hospital pharmacy-prepared prefilled drug products.


Assuntos
Microextração em Fase Líquida , Serviço de Farmácia Hospitalar , Humanos , Microextração em Fase Líquida/métodos , Metanol , Embalagem de Medicamentos , Manejo de Espécimes
18.
Artigo em Inglês | MEDLINE | ID: mdl-38286102

RESUMO

Therapeutic drug monitoring (TDM) is a personalized care tool based on the determination of a target drug concentration in human serum. An antidepressant drug of interest for such investigations is fluoxetine (FXT), due to a severe impact of genetic polymorphisms on its metabolism. A bioanalytical method employed for TDM purposes must exhibit satisfactory selectivity and detectability, which becomes more difficult due to highly complex biological matrices. In this study, a highly selective bioanalytical method for the determination of FXT in human serum is proposed, which provides excellent clean-up efficiency based on a low cost hollow fiber liquid-phase microextraction (HF-LPME) sample preparation step and nano-liquid chromatography coupled to high-resolution mass spectrometry (nano-LC-HRMS). HF-LPME was performed using a two-phase "U" configuration, with 6 cm fiber, 20 µL of 1-octanol acting as supported liquid membrane, and ammonium hydroxide (pH 10) as the donor phase with NaCl (10 % m/v) and methanol (5 % v/v) as additives, requiring only 250 µL of the sample. The procedure was conducted for 30 min under a 750 rpm stirring rate. Gradient elution was carried out employing an acetonitrile-water as mobile phase, the composition of 30:70 to 100:00 (v/v) for 15 min, using formic acid 0.1 % (v/v) as an additive. MS1 was acquired in an Orbitrap mass analyzer, while MS2 was acquired in a linear trap quadrupole. Satisfactory linearity (Pearson's r = 0.99709) was obtained for a concentration range of 0.02 to 2.5 µg mL-1, which is compatible with the therapeutic and toxic range for FXT. The developed method presents adequate precision (1.61 to 7.45 %) and accuracy (95 to 114 %) and allows the dilution of high concentration samples in a 1:4 ratio (v/v), enabling its application for forensic serum samples. To our knowledge, this is the first study reporting a method based on HF-LPME and nano-LC-HRMS with any analytical purpose, especially with a TDM focus.


Assuntos
Fluoxetina , Microextração em Fase Líquida , Humanos , Microextração em Fase Líquida/métodos , Cromatografia Líquida/métodos , Antidepressivos , Espectrometria de Massas em Tandem/métodos , Cromatografia Líquida de Alta Pressão/métodos
19.
Food Chem ; 442: 138433, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38237292

RESUMO

In this work, a switchable deep eutectic solvent (SDES) based on fatty acid and polyetheramine ion pair was prepared for liquid-phase microextraction (LPME) of phenoxyacetic acid herbicides in drinking water, beverage and honey matrices. The as-synthesized SDES equipped with an interesting characteristic of fast and reversible polarity switching, achieving homogeneous extraction and rapid bi-phase separation simultaneously. Several key parameters affecting the extraction performance were investigated comprehensively by Box-Behnken design. Under the optimal conditions, the method exhibited excellent linearity (15-4000 µg L-1), low detection limits (3-5 µg L-1), desirable precision (RSD < 8.1 %), and satisfactory recovery (72.6-98.7 %). More importantly, the introduction of SDES can simplify the pre-treatment procedure, shorten extraction time (4 min), and avoid the usage of traditional organic solvent during the whole extraction process. In addition, the switching mechanism of SDES was characterized by FT-IR and 1H NMR, and the forming mechanism of SDES was investigated using density-functional theory. The green of the method was estimated using the analytical ecological scale, the analytical green calculator, and the green analytical procedure index. The cytotoxicity of SDES was investigated and the result displayed that toxicity of the SDES was very low with the EC50 > 500 mg/L. Therefore, the proposed method was green and efficient and revealed considerable application prospects for the extraction of trace analytes from complex materials.


Assuntos
Acetatos , Água Potável , Herbicidas , Microextração em Fase Líquida , Solventes/química , Solventes Eutéticos Profundos , Espectroscopia de Infravermelho com Transformada de Fourier , Microextração em Fase Líquida/métodos , Limite de Detecção
20.
Food Chem ; 442: 138425, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38242002

RESUMO

This study describes the development of an acid induced dispersive liquid-liquid microextraction method based on the in situ formation of hydrophobic deep eutectic solvents for the extraction of bisphenol A and alkylphenols from environmental water and beverage samples. Hydrochloric acid altered the hydrophilic-hydrophobic state of fatty acid salts to obtain hydrophobic fatty acids, which formed hydrophobic deep eutectic solvents with analytes in situ to extract the analytes. Under optimized conditions, the limits of detection and limits of quantitation were 0.03-0.1 µg L-1 and 0.12-0.3 µg L-1, the intraday and interday relative standard deviations were less than 3.9 %, and the enrichment factor was 29-32. The recoveries of bisphenol A and alkylphenols were 95.9-104.9 % and 86.9-105.0 %, respectively. The extraction process used only hydrochloric acid and fatty acid salts, and the extraction process required less than 1 min. This method has the advantages of simplicity, speed, low cost and environmental friendliness.


Assuntos
Compostos Benzidrílicos , Microextração em Fase Líquida , Fenóis , Água , Água/química , Solventes/química , Solventes Eutéticos Profundos , Microextração em Fase Líquida/métodos , Ácido Clorídrico , Sais , Ácidos Graxos/química , Bebidas , Limite de Detecção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...